MP2 conversion options - step 9 of 13

Convert MP2 equipment meters.

Indicate how to convert MP2 equipment meters into Infor EAM.

MP2 and Infor EAM meter naming functionality differs. MP2 allows the same meter name for multiple pieces of equipment; however, Infor EAM requires that equipment have a unique 20 character meter name. Here are examples from both MP2 and Infor EAM.

Equipment=FORKLIFT1

MP2 Meter Name=HOUR

AND Equipment=BOILER1

MP2 Meter Name=HOUR

In Infor EAM, a unique meter ID is required to allow features such as meter roll down and meter replacement. Here is an example of what you may do for the conversion into Infor EAM:

Infor EAM Example

Meter Name=FORKLIFT1-HOUR

Meter Name=BOILER1-HOUR

The characters are both less than the 20 character maximum of Infor EAM. In this example, the values of both fields were merged and separated by a '-'. If in your equipment and meters list there are not any equipment and meter combinations exceeding the 20 character maximum, you may still separate the values by a '-' and enter the full length of meters. Here is an example:

Prefix Field Start Position Length Suffix
<blank> Equipment 1 14 -
<blank> Meter 1 5

This would guarantee field lengths covered at least the largest equipment/meter combination and was still less than 30 characters. The system will cut off all data at the maximum length specified.

Another option is to sequentially generate meter names, which would give the meter names a unique code with a beginning sequential number that you choose.